MagicWave
(10) Welding voltage display ... for indicating the actual welding voltage value on the
control panel
(continued)
(11) HOLD indicator ... every time you finish a welding operation, the actual values for
(12) Overtemperature indicator ... lights up if the power source overheats (e.g. becau-
(13) HF (high-frequency) ignition is activated ... Set-up parameter "HFt" has been set
(14) Gas-test button ... for setting the required gas flow rate on the pressure regulator.
right-hand display.
Where one of the TIG welding modes has been selected, the right-hand display
reads "0.0" before the start of welding. Where the "Rod electrode (MMA) welding"
mode has been selected, there is a 3-second time lag before the value for the open-
circuit voltage "50V" is displayed.
Important! The value of 50 V indicated where the "Rod electrode (MMA)" process
has been selected refers to the mean value of the pulsed open-circuit voltage.
welding current and voltage are stored, and the "Hold" indicator lights up.
The "Hold" indicator refers to the last value reached by the main current I
as any other parameter is selected, the "Hold" indicator goes out. The "Hold" values
will continue to be available, however, if parameter I
The "Hold" indicator is cancelled whenever:
-
a new welding operation is started
-
the main current I
is adjusted
1
-
the operating mode is changed
-
the process is changed
Important! If the main current phase was never reached, or if a pedal remote
control unit was being used, no "Hold" values are output.
se the duty cycle has been exceeded). For more information on this, see the "Trou-
bleshooting" section.
to a certain interval for the high-frequency pulses
After you press this button, gas will flow out for 30 s. Press the button again to stop
the gas flow before the 30 seconds are up.
12
. As soon
1
is selected again.
1