Technical Specifications; Technical Data - Riello RL 28/1 Manuel D'entretien

Masquer les pouces Voir aussi pour RL 28/1:
Table des Matières

Publicité

TECHNICAL DATA

MODEL
TYPE
OUTPUT
(1)
DELIVERY
(1)
FUEL
- Net calorific value
- Density
- Viscosity at 20 °C
OPERATION
NOZZLES
STANDARD APPLICATIONS
AMBIENT TEMPERATURE
COMBUSTION AIR TEMPERATURE
ELECTRICAL SUPPLY
ELECTRIC MOTOR
MOTOR CAPACITOR
IGNITION TRANSFORMER
PUMP
ELECTRICAL POWER CONSUMPTION
ELECTRICAL PROTECTION
IN CONFORMITY WITH EEC DIRECTIVES
NOISE LEVELS
(2)
(1) Reference conditions: Ambient temperature 20°C - Barometric pressure 1000 mbar - Altitude 100 m a.s.l.
(2) Sound pressure measured in manufacturers combustion laboratory, with burner operating on test boiler and at maximum rated output.
:
VARIANTS
MODEL
CODE
3472013
RL 28/1
3472014
DEGASSING UNIT: optional accessory
It may occur that a certain amount of air is contained in the light oil sucked up by the pump. This air may originate from the light oil itself as a
consequence of depressurization or air leaking past imperfect seals.
In double-pipe systems, the air returns to the tank from the return pipe; in single-pipe systems, the air remains in circulation causing pressure
variations in the pump and burner malfunctions.
For this reason, we advise installing a degassing unit near the burner in single-pipe installations.
Degassing units are provided in two versions:
CODE 3010054 without filter
CODE 3010055 with filter
DEGASSING UNIT CHARACTERISTICS
• Burner delivery
: 80
• Light oil pressure
: 0.7
• Ambient temperature
: 40
• Light oil temperature
: 40
• Attachment connectors
: 1/4

TECHNICAL SPECIFICATIONS

Mcal/h
kg/h
kWh/kg
Mcal/kg
kg/dm
mm
number
°C max
mF/h
V1 - V2
I1 - I2
delivery (at 20 bar)
kg/h
pressure range
° C max
fuel temperature
W max
dBA
Electrical
Blast tube
supply
lenght mm
single-phase
216
single-phase
351
kg/h max
bar max
°C max
°C max
inch
kW
Light oil
11.8
10.2 (10.200 kcal/kg)
3
0.82 - 0.85
6 (1,5 °E - 6 cSt)
2
/s max
• Intermittent (min. 1 stop in 24 hours)
• Single-stage (all - nothing)
2
Boilers: water, steam, diathermic oil
°C
0 - 40
60
V
230 ~ +/- 10%
Hz
50 - single-phase
rpm
W
V
A
8 / 450
bar
IP 44
89/336 - 73/23 - 92/42 - 89/392
11
RL 28/1
657 T1
178 - 332
153 - 286
15 - 28
2800
250
220 / 240
2,1
230 V - 2 x 5 kV
1,9 A - 30 mA
45
10 - 18
60
370
70

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

34720133472014

Table des Matières