Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 69
|+ Button
• Starts and stops door opening.
• During programming, it allows the values of the
parameters to be selected.
|- Button
• Starts and stops door closing.
• During programming, it allows the values of the
parameters to be selected.
SET Button
• Gives access to programming of parameters (see
"Programming sequence" on page 53).
• Confirms and programmes the selected parameter
during programming.
CODE button
• Starts programming of the radio code (remote
control).
Courtesy light
The indicator light remains on during the opening and
closing operations.
Once the door has stopped, the light remains on for
around 3 minutes. Once this time has passed, it goes off
automatically.
It flashes for 3 seconds before starting the closing
operation in automatic mode.
4

OPERATION MODES

Step-by-step mode
Opening
The opening process is initiated by activating the key
command (wall pushbutton, remote control or |+
button on the operator control panel).
The door comes to a stop if a key command is
activated during opening. If the following are then
activated:
• the |+ button on the control panel, the door
continues to open.
• the remote control or wall pushbutton, the door
closes.
DESCRIPTION OF THE PRODUCT
Connectors
To complete the connections, see "Connecting the
operator to the other installation elements" on
page 50.
Display
Indications during operation:
CL
:
door closed
CL
(flashing):
door closing
F1
:
failure due to current
E1
:
failure due to encoder
OP
:
door open
OP
(flashing):
door opening
30
29
28
,
,
:
countdown in automatic closing
St
:
stop
r5
:
waiting for reset
rS
(flashing):
reset
CS
:
stop by closing photocell
PA
:
pause
Instructions during programming:
See "Starting up and programming" on page 53.
Standby
The door remains open indefinitely until the key
command is operated (wall pushbutton, remote control
or the |- button on the control panel).
Closing
The closing process is initiated by activating the key
command (wall pushbutton, remote control or |-
button on the control panel).
If the |+ or |- button is activated during closing, the
door stops and remains on standby.
If the remote control or wall pushbutton is activated
during closing, the door reverses operation direction
and opens completely.
NAOS garage door opener operator