STARTING UP AND PROGRAMMING
Step 11 (menu 11): opening speed
Step 12 (menu 12): closing speed
60
Installation guide
1 With the display showing 11, press SET once:
number 1 will start flashing on the display (this is the
preset value for this parameter).
2 Pressing the |+ and |- buttons, select the value
required for the operator's opening speed:
1: minimum speed
2, 3: intermediate values
4: maximum speed
3 Once the required value is selected, press SET to
confirm and save it.
4 Press the |+ button once to access the next
M278P11
programming step.
In steps 4 to 12 (menu 4 to 12), programming can
be finished in advance by holding down SET (until
CL is displayed), without having to continue
advancing using the |+ button.
1 With the display showing 12, press SET once:
number 1 will start flashing on the display (this is the
preset value for this parameter).
2 Pressing the |+ and |- buttons, select the value
required for the operator's closing speed:
1: minimum speed
2, 3: intermediate values
4: maximum speed
3 Once the required value is selected, press SET to
confirm and save it.
4 Hold the SET button down for 5 seconds to leave
programming mode. The display will show CL,
indicating that the operator is in use mode.
M278P12