STARTING UP AND PROGRAMMING

1

CONNECTION TO THE ELECTRICITY SUPPLY AND CHECK

1 Connect the operator to the electricity supply.
In order to know the requirements of the
mains connection, see "Electrical power
supply installation" on page 42.
The correct operation of the operator and of the
complete system will only be achieved after
programming. However, before programming it
is necessary to check that all the elements work,
carrying out the checks listed below.
Before carrying out any door movement,
ensure there is no person or object in the
radius of action of the door and the drive
mechanisms.
2

PROGRAMMING SEQUENCE

2 Briefly press the |+ and |- buttons on the operator
control board once or twice to check correct
operation.
3 Activate the wall key or pushbutton to check it
works.
O
Before starting programming, manually move the
door to interlock the drag carriage.
1 SET BUTTON: Pressing the SET button accesses the
menus to programme opening and closing and
adjust the parameters (see "Setting parameters (SET
button)" on page 54). The menus included are as
follows:
1: programming opening position
2: programming closing position
3: opening and closing forces
4: sensitivity during opening
5: sensitivity during closing
6: type of radio (Fixed or Roller Code)
7: step-by-step or automatic closing mode, and
M278B
8: slowdown distance in closing
9: opening mode
10: operations counter
11: opening speed
12: closing speed
2 CODE BUTTON: Pressing the CODE button will
carry out radio code programming (see "Radio code
programming (CODE button)" on page 61).
standby time in automatic mode
NAOS garage door opener operator