Automatic mode (F101)
Opening: this begins by activating the operation device
(emitter, magnetic key, key selector, etc).
• Community Opening: during opening, the control
panel does not obey the operation device
commands (configurable in the advanced options
menu, see "Advanced Functions Programming (D1=
"A")" on page 57).
Semi-automatic mode (F102)
Opening: this begins by activating the operation device
(emitter, magnetic key, key selector, etc).
• Step-by-step opening: if the control device is
operated
during
(programmable in the advanced options menu, see
"Advanced Functions Programming (D1= "A")" on
page 57).
The display shows pause situation
The gate closes when the operation device is activated
again.
5
BEHAVIOUR IN THE FACE OF AN OBSTACLE
The gate can detect an obstacle in two ways:
A- Detection by photocell or safety strip
Opening safety device (SG.A)
During opening: if, during opening, the opening
safety device (SG.A) is activated, the gate inverts
operation direction and slightly closes. The gate
remains on standby until an operation command is
received and the display shows PAC4.
During closing: if, during closing, the opening safety
device (SG.A) is activated, the gate continues to close.
B- Direct detection (built-in safety)
During opening
If, during opening, the gate collides with an obstacle, it
inverts operation direction and slightly closes. The gate
remains on standby until an operation command is
received and the display shows PAF1 or PAE1. The gate
closes when the operation device is used.
46
Installation Manual
opening,
the
gate
halts
PA
.
S t a n d b y : t h e g a t e r e m a i n s o p e n d u r i n g t h e
programmed time.
• If the control device or the photocells are operated
during standby, standby time restarts (configurable
in the advanced options menu, see "Advanced
Functions Programming (D1= "A")" on page 57.
Close:the closing operation starts automatically once
standby time is finished.
If, during closing, the operation device is activated,
the gate inverts operation direction and opens
completely.
Standby: the gate remains open indefinitely until the
control device is operated.
Close: the closing process starts up by using the
operation device.
If, during closing, the operation device is activated,
the actuator inverts the movement and the gate
opens.
Closing safety device (SG.C)
During opening: if, during opening, the closing safety
device (SG.C) is activated, the gate continues to open.
During closing: if, during closing, the closing safety
device (SG.C) is activated, the gate inverts operation
direction and opens completely. The display shows
OPC5.
During closing
If, during closing, the gate collides with an obstacle, it
inverts operation direction and opens completely. The
display shows OPF1 or OPE1.