4 OPERATION

4.2 Operation Mode Display

The following variables are displayed in the operation mode:
45,6 L/ m
16,45 m A
80529 L
6247 L. .
4.3 Calibration Mode
Press
ENTER
The following variables can be set in the parameter definition menu:
LANGUAGE
UNIT
K-FACTOR
CURRENT
PULSE
RELAY
FILTER
TOTAL
CODE
END
Flow rate in the required engineering unit (see calibration
menu).
4...20 mA output signal, proportional to the flow
according to the selected measuring range
Main totalizer in the required engineering unit (see calibration
menu). Reset in the calibration menu.
Daily totalizer in the same engineering unit as the main
totalizer. A point behind the unit differentiates it from the main
totalizer. Reset by simultaneously pressing the
for 2 seconds.
simultaneously for 5 seconds
Language selection between English, German, French,
Italian....
Selection of engineering units to display flow rate and
totalizer.
Input of K-factor according to chart or Teach-in function in
order to determine the specific K-factor.
Determination of 4...20 mA measuring range.
Parameter definition of pulse output (unit and quantity).
OR definition of pulse output relay REED (unit and quantity).
Parameter definition of relays. This message only appears if
the relay option has been installed. (not for relay REED)
Dampening selection. There are ten different steps available.
Totalizer resetting.
For internal Bürkert use only.
Return to operation mode and storage of new parameters.
E-16-
FLOW TRANSMITTER 8035