3 INSTALLATION REED
3.4.6 SE35 with relay REED and 115/230 VAC (option)
Remove the cover of the transmitter, the power supply board is in the bottom of the
housing. Pull the cable through PG 13,5 and connect according to fig. 3.8.
The connection of the output signals (current and pulse on relay REED) is identical to the
connection of the transmitter type SE35 with relay REED version 12/30 VDC.

SE35 with relay REED

mA
Fig. 3.11 Transmitter SE35 with relay REED and 115/230VAC power supply
If the current output 4...20 mA is not used: set the switch 1 in position A (fig.
!
3.10) and the strap between 1-3 (fig. 3.9).
230 VAC
L1
115 VAC
N
Switch 1 in position A
Sensor connection
FLOW TRANSMITTER 8035
1 2 3 4
Strap (cf §3.4.2)
SE35 REED
E-14-
+
-
5 6
8035