2 SPECIFICATION

2.4 Technical Data

Pipe diameter
Measuring range
flow range
flow range
Plastic fitting
Pressure class
Fluid temperature max
Metal fitting
Pressure class
Fluid temperature max:
Ambiant temperature
Storage temperature
Relative humidity
Enclosure
Measuring error
Linearity
Repeatability
Display
Sensor holder
Paddle-wheel
Axis and bearing
Electronics housing
Voltage supply
Output signal
Load
Pulse output
Pulse output relay REED
Relay output (optional)
(*) Under reference conditions i.e. measuring fluid water, ambient and water temperature 20°C,
applying the minimum inlet and outlet pipe straights, matched pipe dimensions.
o.F.S. = of standard Full Scale (10 m/s) - o.R. = of Reading
from DN 15 to DN 50 (1/2" to 2")
0,3 to 10 m/s (1.0 to 32.8 ft/s)
as from 3 l/min (DN15 pipe, 0.3 m/s flow velocity)
as from 0.8 gpm (1/2" pipe, 1.0 ft/s flow velocity)
PVC; PP; PVDF
PN10
PVC: 50 °C (132°F); PP: 80 °C (176°F); PVDF: 100 °C (212°F)
Stainless-stel (316L 1.4404); brass
PN16
100 °C (212°F)
0 to 60 °C (32 to 140 °F)
0 to 60 °C (32 to 140 °F)
80 %
IP65
1.With In-line calibration (Teach-In):
≤±0.5% o.F.S. (at 10 m/s)
2.With standard mean K-Factor:
≤± (0.5% o.F.S. +2.5% o.R.)
≤±0.5% o.F.S. (at 10 m/s)
*
0.4% o.R.
15 x 60 mm LCD 8 digits, alphanumeric,
15 segments, 9 mm high
PVDF, PP, PVC, SS 316L (1.4404), Brass
PVDF
ceramic; O-rings FPM
PC; Front plate foil polyester
12...30 VDC (115/230 V as an option)
4...20 mA
max. 900 Ω at 30V; max. 500 Ω at 24V; max. 100 Ω at 15V;
max. 800 Ω at 115/230 VAC
Open collector NPN and PNP,
0...30 V, 100 mA, protected, freely adjustable
Contact relay REED, closing 0,1 s.
Opening depending on flow rate (0.1 s min. U max: 34 V, 0.2 A
2 relays, 3 A, 220 V, freely adjustable
E-6-