For the version with 4 switching points, the following menu appears:
2s
3s
NOTES:
• If "LOC" appears in the display when attempting to change a setting,
programming is disabled.
Action: Set the programming enable(s) to "free".
(see section 10 "Programming Enables")
• If the ; key
advance automatically.
• Whenever settings have been altered, "PROG" appears briefly in the display
when the display switches over. The new setting has been saved in the unit.
7.4

SETTING RANGES FOR THE SWITCHING OUTPUTS

(switching point minus switching hysteresis = switch-back point)
Rod length
Measuring range
in cm
in cm
25.0
17.8
28.0
20.8
37.0
29.8
41.0
33.8
52.0
44.8
73.0
65.8
Rod length
Measuring range
in inch
in inch
9.85
7.00
11.05
8.15
14.60
11.70
16.15
13.30
20.50
17.60
28.8
25.9
Switching point in °C *
-23.0 .. +100.0
Switching point in °F *
-9 .. 212
* All ranges given in the table can be adjusted by the increments shown and apply when the
offset is zero.
Version 2018/07/06
2s
or key
is held down while changing a setting, the value will
Switching point
in cm *
0.3 .. 17.8
0.4 .. 20.8
0.5 .. 29.8
0.6 .. 33.8
0.7 .. 44.8
1.0 .. 65.8
Switching point
in inch *
0.15 .. 7.00
0.15 .. 8.15
0.20 .. 11.70
0.20 .. 13.30
0.30 .. 17.60
0.4 .. 25.9
Switching hysteresis in °C *
0.8 .. 123.6
Switching hysteresis in °F *
2 .. 222
HYDAC ELECTRONIC GMBH
HYDAC
2s
mode
Switching
hysteresis
in cm *
0.1 .. 17.6
0.2 .. 20.5
0.2 .. 29.5
0.2 .. 33.4
0.3 .. 44.3
0.4 .. 65.1
Switching
hysteresis
in inch *
0.05 .. 6.90
0.05 .. 8.05
0.10 .. 11.55
0.10 .. 13.15
0.10 .. 17.40
0.2 .. 25.6
Increment in °C
0.2
Increment in °F
1
Page 12
Actual
display
Increment
in cm *
0.1
0.1
0.1
0.1
0.1
0.1
Increment
in inch*
0.05
0.05
0.05
0,05
0.05
0.1
Part No. 669927