Setting Ranges For Switching Outputs; Basic Settings; Altering The Basic Settings - HYDAC ELECTRONIC ETS 300 Notice D'utilisation

Thermocontacteur electronique
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ETS 300
.4

SETTING RANGES FOR SWITCHING OUTPUTS

7
Switching point function
Sensor
Unit
°C
ETS 320
°F
°C
ETS 380
°F
Window function
Sensor
Unit
°C
ETS 320
°F
°C
ETS 380
°F
* All ranges given in the table are adjustable by the increments shown.
8

Basic settings

In order to adapt the unit to a particular application, the function of the ETS 300 can be altered via
several basic settings. These are combined in one menu.

8.1 ALTERING THE BASIC SETTINGS

NOTE:
• When the menu is activated no switching operations are carried out.
• Switch off supply voltage or disconnect the unit from the supply voltage.
To close the basic setting menu:
Call up the menu point "END", set to "YES", the ETS 300 returns to the normal display mode after
2 seconds.
NOTE:
• If after about 50 seconds no keys have been pressed, the menu automatically closes
down. Any changes which may have been made will not be saved.
Status: 29.01.2014
Display
Switching point
-25 .. 100
-22 .. 100
-13 .. 212
-10 .. 212
-30 .. 150
-27 .. 150
-22 .. 302
-16 .. 302
Display
Lower switch value
-25 .. 100
-23 .. 99
-13 .. 212
-11 .. 211
-30 .. 150
-28 .. 149
-22 .. 302
-18 .. 300
(for summary see 8.2)
HYDAC ELECTRONIC GMBH
Hysteresis
Increment*
1 .. 123
1
1 .. 223
1
1 .. 178
1
2 .. 320
2
Upper switch
Increment*
value
-22 .. 100
1
-10 .. 212
1
-27 .. 150
1
-16 .. 302
2
Part No.: 669651 E
9