HNS 3000
14 Order Details
Temperature sensor
1 =With temperature sensor
2 =Without temperature sensor
only possible with output options "2", "3" and "5"
Mechanical connection
2 = G 3/4 A ISO 1179-2
Electrical connection
6 = Connector male M12x1, 4-pole
only possible with output options "2" und "3"
(without female connector)
8 = Connector male M12x1, 5-pole
only possible with output options "5"
(without female connector)
P = Connector male M12x1, 8 pole
only possible with output options "8"
(without female connector)
Output
2 =2 switching outputs
(in conjunction with electrical connection type "6" only)
3 =1 switching output and 1 analogue output
(in conjunction with electrical connection type "6" only)
5 =2 switching outputs and 1 analogue output
(in conjunction with electrical connection type "8" only)
8 =4 switching outputs and 2 analogue outputs
(in conjunction with electrical connection type "P" only)
Probe length (physical)
0250, 0280, 0370, 0410, 0520, 0730 mm
Modification number
000 = Standard (determined by manufacturer)
Version 2018/07/06
HYDAC ELECTRONIC GMBH
HNS 3 X 2 X – X –XXXX – 000
Part No. 669927
Page 25