HNS 3000
7.2
ANALOGUE OUTPUT
The versions with 1 or 2 switching points can have an analogue output as an option. The
output can be switched to either 4 .. 20 mA or 0 ... 10 V (corresponding to measuring
range) via the basic menu and can be assigned to fluid level or to temperature (optional).
The versions with 4 switching points have two 0 ..10 V analogue outputs
In this case fluid level and temperature are permanently assigned to an output.
7.3
SETTING THE SWITCHING POINTS AND HYSTERESES OR SWITCHING
RANGES FOR WINDOW MODE
• Press the "mode" key.
• Either "S.P.1" or "Hi.1" will appear in the display.
• Keep pressing the mode key repeatedly to scroll through to the required parameters.
("S.P.1", "hYS.1", "S.P.4" or "hYS.4" appears when switching point mode is set; "Hi.1",
"Lo.1", "Hi.4" or "Lo.4" appears when window mode (WIN) is set)
• After 2 seconds have elapsed, the actual setting will flash.
• Use the
and
• If necessary, use the "mode" key to select further parameters and the
to alter the settings.
• If no key has been pressed for 3 seconds, the display will revert to displaying the
primary display and the settings will be saved to the unit.
HYDAC
mode
Press "mode" key until the
required parameter
appears.
For the version with 1 or 2 switching points, the following menu point appears:
→
→
3s
3s
Version 2018/07/06
keys to alter the settings.
→
→
2s
Actual switching
Display
point 1
HYDAC
mode
HYDAC ELECTRONIC GMBH
HYDAC
mode
Setting the switching points
= reduce value
= increase value
Actual
display
Page 11
and
keys
HYDAC
→
3s
mode
Part No. 669927