Servicing
11.4

Installing the dosing valve in the correct position

Personnel:
Protective equipment:
WARNING!
During installation it is essential to ensure that the valves are installed
according to the direction of flow!
NOTICE!
It is essential that the tightening torques given below are observed, firstly to
ensure the leak-tightness of the system and secondly to ensure the integrity
of the thread.
The tightening torques of the metering head screws are given on an
adhesive label that is affixed to the pump head.
Tightening torque of the suction/pressure valves:
Pump head size
Tightening torque
11.5

Changing the valve cartridges (V3 type)

NOTICE!
When changing 'V3 Valve cartridges' make sure they are installed in the
correct position.
S
417102276 Rev. 5-02.2020
n
Mechanic
n
Service personnel
n
Specialist
n
Chemical-resistant protective gloves
n
Protective eyewear
The direction of flow is marked by an impressed arrow on the suction/
pressure valves.
5 l/h and 11 l/h
2 ± 0.2 Nm
1
5 l/h and 11 l/h
2,8 ± 0.2 Nm
1 Lower valve cartridge V3
S Suction side -> suction valve
1
162
5 l/h and 11 l/h
4 ± 0.2 Nm