Alarm relay

The functional method of the alarm output and the response of the pump on an alarm can
be defined here. The alarm relay can be used to indicate when the pump stops, i.e. when
it is switched off unintentionally via the display button. This function can be used to
indicate the operational readiness of the pump to a remote monitoring unit.
Fig. 58: Configuration: Alarm relay
Factory setting: Disabled in the event of an alarm
[Alarm relay] - setting:
1.
[Call up the Main menu] :
2.
[Configuration] - setting:
3.
Using the scrollbar on the right side of the screen, scroll to the [Alarm relay] .
4.
[Select Alarm relay] .
ð Screen change for the setting: [Alarm relay]
5.
If required, select the selection field 'Deactivated in the event of an alarm' .
(in the event of an alarm, the alarm output is "open")
ð The selection field 'Deactivated in the event of an alarm' is marked ü.
6.
[ Click Next]
ð Screen switches to the query 'Display pump stop' .
7.
If required, select the selection field 'Display pump stop' .
ð The selection field 'Deactivated in the event of an alarm' is marked ü.
8.
Press the
ð The setting is saved, and the screen switches back to the configuration overview.
9.
By pressing the
10. By pressing the
417102276 Rev. 5-02.2020
The external alarm input is connected to
terminal 1, terminal 2 and terminal 3 as shown below.
The following should be noted here:
n
Voltage-free contact (relay)
n
max. external voltage: 230 V, AC/DC, max. 3 A.
n
Reserve signal: Contact closed / opened approx. 500 ms
4
5
3
Ä Chapter 7.7 'Main menu' on page 73
Ä Chapter 7.10 'Overview - Configuration' on page 92
to save the setting.
button.
button, you can return to the [main menu].
button, you can return to the [operating display].
Ä Chapter 6.4 'Electrical installation' on page 56