Metro 800 RTS / Metro 1000 RTS
Maintenance required indicator
Values
0: no indication
1: 100 cycles
to
99 : 9900 cycles (number of cycles = value x 100 cycles)
Comments
Once the motor reaches the programmed number of cycles,
signal that maintenance is required.
indicator must be deactivated.
Detection of forced entry
Values
0: no detection of forced entry
1: obvious forced entry detected
2: less obvious forced entry detected
Comments
Detection of forced entry starts operating 30 seconds after
the door is closed.
If forced entry is detected, the siren sounds for 2 minutes.
To stop it, press one of the buttons on the remote control.
If photoelectric cells are installed (P2=2), these must be
connected to the permanent power supply (refer to the
installation manual for the siren).
Safety action prior to opening (safety ADMAP)
Values
0: no effect
1: movement rejected
Comments
If value 1 is selected, triggering the safety input will inhibit
door opening.
Safety action during closure
Values
1: stop
2: stop + partial re-opening
3: fully reopen
Comments
Value 1 is not allowed when using a sensor bar on the
safety input.
Obstacle detection action during closure
Values
2: stop + partial re-opening
3: fully reopen
Total operating mode automatic timed close
Values
0 to 12 (time delay value = value x 10 s)
2:20 s
Lighting time delay
Values
0 to 60 (time delay value = value x 10 s)
6:60 s
Partial operating mode automatic timed close
Values
0 to 12 (time delay value = value x 10 s)
2:20 s
Programming example:
setting the "
(Fig. 31)
Setting up a long soft stop function zone"P7" = 2.
Copyright © 2016 Somfy SAS. All rights reserved
P7
" closure approach speed
Special case: adjusting the position of the door for partial
opening (Fig. 32)
Move the door to the desired partially open position:
- Pressing and holding the "-" button will close the door.
- Pressing and holding the "+" button will open the door.
-
OK".
-
SET".
Forced mode (Fig. 33)
This function makes it possible to manipulate the door at any moment (loss of
remote control, photoelectric cell fault, etc.).
Door stationary:
- press the "-" button to close it
- press the "+" button to open it.
Door moving: press the "-" or "+" button to stop the door.
Memorising the remote control for operation in «Partial opening»
mode (Fig. 34)
Memorising the remote control for controlling remote lighting
(Fig. 35)

8 - SPECIAL OPERATION

Refer to the user manual.
Adding a remote control without accessing the motor head (see
user guide Fig. 12a et 12b)
9 - CLEARING REMOTE CONTROLS AND
ALL SETTINGS

9.1 Clearing remote controls - Fig. 37

PROG" button until the light blinks (7 s).
This clears all of the remote controls memorised.

9.2 Resetting all settings - Fig. 38

SET" button until the light goes out (7 s).
This clears all previously stored settings and returns them to their default
values.

10 - LOCKING PROGRAMMING - FIG. 39

The keypad must be locked to ensure the safety of the end-users.
Non-observance of this instruction can result in serious injury to
persons, e.g. when trapped by a door.
SET", "+", "-" buttons:
-
SET".
- the "+" and "-" buttons must be pressed simultaneously within 2 seconds.
To access programming mode once again, repeat the same procedure.

11 - REFITTING COVERS - FIG. 40

one of the two positions shown in Fig. 40.
OK".
WARNING
EN
9