Dexxo Pro RTS
Maintenance required indicator
Values
0: no indication
1: 100 cycles
to
99 : 9900 cycles (number of cycles = value x 100 cycles)
Comments
Once the motor reaches the programmed number of cycles,
the integrated light flashes each time the door moves to
signal that maintenance is required.
To stop the integrated light flashing, either the current
value must be confirmed or modified, or the maintenance
indicator must be deactivated.
detection of forced entry
0: no detection of forced entry
Values
1: obvious forced entry detected
2: less obvious forced entry detected
Comments
Detection of forced entry starts operating 30 seconds after
the door is closed.
If forced entry is detected, the siren sounds for 2 minutes.
To stop it, press one of the buttons on the remote control.
If photoelectric cells are installed (P2=2), these must be
connected to the permanent power supply (refer to the
installation manual for the siren).
safety action prior to opening (safety AdMAP)
0: no effect
Values
1: movement rejected
Comments
If value 1 is selected, triggering the safety input will inhibit
door opening.
safety action during closure
Values
1: stop
2: stop + partial re-opening
3: fully reopen
Comments
Value 1 is not allowed when using a sensor bar on the
safety input.
obstacle detection action during closure
Values
2: stop + partial re-opening
3: fully reopen
total operating mode automatic timed close
Values
0 to 12 (time delay value = value x 10 s)
2:20 s
Lighting time delay
Values
0 to 60 (time delay value = value x 10 s)
6:60 s
Partial operating mode automatic timed close
Values
0 to 12 (time delay value = value x 10 s)
2:20 s
Programming example:
setting the "
(Fig. 31)
setting up a long soft stop function zone"P7" = 2.
9
P7
" closure approach speed
special case: adjusting the position of the door for partial
opening (Fig. 32)
Select setting "P6" and validate by pressing "oK".
Move the door to the desired partially open position:
- Pressing and holding the "-" button will close the door.
- Pressing and holding the "+" button will open the door.
- Validate by pressing "oK".
- Exit the menu with "set".
Forced mode (Fig. 33)
This function makes it possible to manipulate the door at any moment (loss of
remote control, photoelectric cell fault, etc.).
Door stationary:
- press the "-" button to close it
- press the "+" button to open it.
Door moving: press the "-" or "+" button to stop the door.
Memorising the remote control for operation in «Partial opening»
mode (Fig. 34)
Memorising the remote control for controlling remote lighting
(Fig. 35)
Memorising a telis or similar type remote control (Fig. 36)

8 - sPeCIAL oPerAtIon

refer to the user manual.
Adding a remote control without accessing the motor head (see
user guide Fig. 12a et 12b)
9 - CLeArIng reMote ControLs And
ALL settIngs

9.1 Clearing remote controls - Fig. 37

Press the "Prog" button until the light blinks (7 s).
This clears all of the remote controls memorised.

9.2 resetting all settings - Fig. 38

Press the "set" button until the light goes out (7 s).
This clears all previously stored settings and returns them to their default
values.

10 - LoCKIng ProgrAMMIng - FIg. 39

the keypad must be locked to ensure the safety of the end-users.
non-observance of this instruction can result in serious injury to
persons, e.g. when trapped by a door.
Pressing the "set", "+", "-" buttons:
- start by pressing "set".
- the "+" and "-" buttons must be pressed simultaneously within 2 seconds.
To access programming mode once again, repeat the same procedure.

11 - reFIttIng CoVers - FIg. 40

Position the aerial and fit the covers.
To ensure proper remote control range, the aerial must be fitted in
one of the two positions shown in Fig. 40.
WArnIng