Dexxo Pro io
> To determine the operating mode in which a button is
programmed
When the saved button and the "STOP
- beeps twice, the button is programmed for partial opening,
- beeps 3 times, the button is programmed for full opening.

10 - SPECIAL OPERATION

If there is a power outage while the door is being opened, when the power is
restored the door should return to its opening stop; if the door does not reach
its opening stop, it cannot be closed.
11 - CLEARING REMOTE CONTROLS AND
ALL SETTINGS

11.1 Clearing remote controls - Fig. 48 to 50

> Clearing Keytis or Keygo remote controls
Individually clearing a remote control button
- by programming from the Dexxo Pro motor (Fig. 20).
Programming a previously programmed button automatically clears any
previously stored programming settings.
- by directly clearing the remote control (only for Keytis remote controls)
(Fig. 48).
Simultaneously press the "PROG
the remote control.
> Clearing all remote controls (Fig. 49)
[1]. Press the "PROG
- Clear the system key memorised by Dexxo Pro,
- Clear the programming for all memorised remote controls.
[2]. For Keytis remote controls, repeat the direct clearing procedure for all of
Fig. 48.
> Keytis remote control general reset (Fig. 50)
Simultaneously press the "PROG
- perform a program general clear action (all buttons),
- clear all settings from the remote control (refer to Keytis io remote control
documentation),
- change the system key memorised by the remote control.
11.2 Resetting all settings - Fig. 51
Press the "SET
This clears all previously stored settings and returns them to their default
values.

12 - LOCKING PROGRAMMING - FIG. 52

The keypad must be locked to ensure the safety of the end-users.
Non-observance of this instruction can result in serious injury to
persons, e.g. when trapped by a door.
Pressing the "SET
"-" buttons
- start by pressing "SET
- the "+" and "-" buttons must be pressed simultaneously within 2 seconds.
To access programming mode once again, repeat the same procedure.

13 - REFITTING COVERS

11
BUTTON to be cleared on
KEY
WARNING
(Fig. 53).

14 - TROUBLESHOOTING

14.1 Operating codes displayed

Code
Description
Waiting for a command
Door opening
Waiting for the door to close
Door closing
Obstacle detection
Safety input active
Pedestrian door safety
contact active
Safety mechanism self test
Working from back-up battery
Waiting for a command

14.2 Programming codes displayed

Code
Description
Comments
Awaiting setting
Pressing the "SET
learning mode.
Learning mode
Pressing the "OK
cycle.
Pressing the "+
motor in forced mode.
Awaiting motor
Pressing a remote control button will assign
control memorisation
this button to motor control.
Add a remote
Displayed during remote control
control
programming. (One-way controls).
Delete a remote
Displayed during remote control deletion.
control
(One-way controls)
One-way control
Displayed on reaching the maximum number
memory full
of channels that can be saved.
One-way control
Displayed when all the one-way remote
memory empty
controls have been deleted.

14.3 Error and failure codes displayed

Code
Description Comments
Maximum
During learning,
force reached
the door requires
too much force for
the motor.
Safety
The safety device
mechanism
self test failed
self test fault
Other faults
These codes
and failure
correspond to
conditions
various electronic
circuit board
failures.
For any other error or failure code, please contact Somfy
Comments
Displayed during obstacle
detection then for 30 s.
Displayed after a movement
request or during movement, when
the safety input is active.
This display is maintained as long
as the safety input is active.
Displayed after a movement
request or during movement, when
the pedestrian door contact is
open.
The display is maintained as long
as the pedestrian door contact
remains open.
Displayed during safety
mechanism self tests.
"-" buttons will control the
Action required?
Check door balance and
correct operation by manual
operation.
Check that "P2
correctly depending on the
devices connected to the safety
input.
Check safety device wiring.
When photoelectric cells
are used, check their proper
alignment.
Cut the power supply (mains &
battery back-up), wait for a few
minutes then re-connect the
power supply.
If the fault persists, contact
Somfy Technical Support.