7 - SETUP

7.1 Meanings of the various parameters

(Boldface text = default values)
Total operating mode
Values
0: sequential
1: sequential + timed close
2: automatic closure
3: automatic closure by cells
Comments
P0 = 0: Each press on the remote control causes the
motor to move (initial position: door closed) as per the
following cycle: open, stop, close, stop, open...
P0 = 1: Automatic closure mode operation is only possible if
In sequential mode with automatic timed close:
- the door is closed automatically after the timed delay
- pressing a button on the remote control interrupts the
movement taking place and the timed close.
P0 = 2: Automatic closure mode operation is only possible if
In automatic closure mode:
- the door is closed automatically after the timed delay
- pressing a button on the remote control during opening
has no effect,
- pressing a button on the remote control during closing
causes it to reopen,
- pressing a button on the remote control during the timed
close restarts the timed delay.
P0 = 3: Automatic closure mode operation is only possible if
After the door is opened, movement in front of the cells (safe
seconds).
If there is no movement in front of the cells, the door will close
automatically after the timed close programmed in parameter
t0".
If there is an obstacle in the cells' detection zone, the door will
not close. It will close once the obstacle is removed.
Orange warning light
Values
0: without advance warning
1: with 2 s advance warning
Comments
If the garage opens onto a public road, always select with
advance warning: P1=1
Safety input
Values
0: no safety mechanism
1: safety mechanism with self test
2: safety mechanism without self test
Comments
If value 0 is selected, the safety input is not taken into
account.
If value 1 is selected, the system's self test is run at the
start of every operating cycle.
If value 2 is selected, the safety system runs without a self
test: it is essential to test its proper operation every six
months.
Obstacle detection
sensitivity
Values
0: very low sensitivity
1: low sensitivity
2: standard
3: high sensitivity
obstacle detection complies with annex A of the standard EN 12 453.
Non-observance of this instruction can result in serious injury to
persons, e.g. when trapped by a door.
8
t0",
t0",
WARNING
Partial operating mode
Values
0: sequential
1: sequential + timed close
Comments
P4 = 0 : Each press on the remote control causes the motor
to move (initial position: door closed) as per the following
cycle: open, stop, close, stop, open...
P4 = 1: Automatic closure mode operation is only possible if
In sequential mode with automatic timed close:
- the door is closed automatically after the timed delay
- pressing a button on the remote control interrupts the
movement taking place and the timed close.
Closing speed
Values
0: slowest speed: approx. 3.5 cm/s
to
9: fastest speed: approx. 18 cm/s
By default, 6: approx. 12 cm/s
Comments
If spurious detection of obstacles occurs when this
programming will have to be carried out again.
obstacle detection complies with annex A of the standard EN 12 453.
Non-observance of this instruction can result in serious injury to
persons, e.g. when trapped by a door.
Partially open position
Values
Storing the position as illustrated in Fig. 32.
Closure approach speed
Values
0: no slowdown
1: short soft stop
2: long soft stop
Comments
P7=0: the door does not slow before closure.
P7=1: the door speed slows 20 centimetres before closure.
P7=2: the door speed slows 50 centimetres before closure.
If spurious detection of obstacles occurs when this
programming will have to be carried out again.
obstacle detection complies with annex A of the standard EN 12 453.
Non-observance of this instruction can result in serious injury to
persons, e.g. when trapped by a door.
Opening speed
Values
0: slowest speed: approx. 3.5 cm/s
to
9: fastest speed: approx. 18 cm/s
Choice of operating direction (type of door)
Values
0: direction 1: all types of doors except swinging doors
1: direction 2: swinging doors
Comments
be repeated along with self-learning.
Metro 800 RTS / Metro 1000 RTS
WARNING
WARNING
Copyright © 2016 Somfy SAS. All rights reserved

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Wisniowski metro 1000 rts

Table des Matières