Technical Specifications; Dimensions - SOMFY WISNIOWSKI Metro 800 RTS Manuel D'installation

Masquer les pouces Voir aussi pour WISNIOWSKI Metro 800 RTS:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 36
Metro 800 RTS / Metro 1000 RTS

13 - TECHNICAL SPECIFICATIONS

BASIC TECHNICAL CHARACTERISTICS
Mains supply
Standby
Max. power
consumption
Operation
Peak force
Traction force
Starting force
Use
Number of Opening/Closing cycles
per day
Max. speed
Programming interface
Operating temperature
Travel end limits
Electrical insulation
Built in lighting
Radio frequency
Number of channels that can be
memorised
CONNECTIONS
Type
Safety input
Compatibility
Pedestrian door safety input
Wired control input
Remote lighting output
Orange light output
24 V controlled power supply output
Safety input test output
Accessory power supply output
Remote aerial input
Backup battery
input
Autonomy
Charge time
OPERATION
Forced operation mode
Independent lighting control
Lighting time delay (after movement) Programmable : 0 s to 600 s
Automatic closing mode
Orange light pre-warning
While closing
Before opening
Safety input
(Dangerous
operation
Movement Area
Accessible to the
Public)
Built-in obstacle detection
Operation when an obstacle is
detected
Copyright © 2016 Somfy SAS. All rights reserved
Metro 800 RTS
Metro 1000 RTS
230 V - 50 Hz
5 W
600 W(with 500 W remote lighting)
800 N
1000 N
(1)
650 N
800 N
20 cycles max. per day with a
standard rail - 50 cycles max. per
day with a high performance rail
tested for 36,500 cycles with a
standard rail and 90,000 cycles with
a high performance rail
18 cm/s
7 buttons - 2 character LCD display
- 20 ° C / + 60 ° C - indoor dry - IP 20
Mechanical stopper at opening
Memorized end limit position at
closing
Class 2: double insulation
24 V / 21 W ; BA15s socket
433,42 MHz
< 10 mW
32
Dry contact: NC
Sensor strip with dry contact output
Dry contact: NC
Dry contact: NO
230 V - 500 W - class 2
Halogen or incandescent only
control
Yes: for possible photoelectric TX/RX
cell self-test
strip self-test
24 V - 500 mA max
Yes: RTS aerial compatible (Réf.
2400472)
Yes: battery pack compatible (Réf.
9001001)
24 hours; 5 to 10 cycles depending
on door
48 hours
Pressing the motor control button
Yes for remote lighting
Yes: programmable closing time
delay from 0 to 120 s
Programmable: with or without prior
warning (duration set to 2 s)
Programmable: Stop - Partial
reopening - Full reopening
Programmable: no effect or motion
refused
Adjustable sensitivity: 4 levels
Programmable : partial re-opening or
full reopening
Preset partial opening command
Progressive start up
Opening speed
Closing speed
Closure approach speed
Troubleshooting
Maximum load for motor to start and drive door for at least 5 cm (according
(1)

13.1 Dimensions

Overall length: 3,295 / 3,895
Longueur hors tout : 3303 / 3903
Available travel: 2,555 / 3,155
171 min
140
63,6
Fixation: 2,982 / 3,582
Rail: 2,900 / 3,500
Overall length: 3,153 / 3,753
Longueur hors tout : 3162 / 3762
Rail : 2,900 / 3,500
Yes can be selected: adjustable
partial opening position
Yes
Programmable from 3.5 cm/s to 18
cm/s: 10 possible values
Programmable from 3.5 cm/s to 18
cm/s: 10 possible values
Programmable: does not slow down,
short slowdown zone (30 cm),
long slowdown zone (50 cm)
Recording and accessing data: Cycle
counter, cycle counter with obstacle
detection, number of radio channels
stored, history of the last ten defects
recorded.
Course utile : 2551 / 3151
Fixation : 2981,7 / 3581,7
Rail : 2900 / 3500
412
Rail : 2900 / 3500
116,5
233
EN
318
258
11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Wisniowski metro 1000 rts

Table des Matières