Special Operation; Power Outage - SOMFY Dexxo Optimo RTS Manuel D'utilisation

Masquer les pouces Voir aussi pour Dexxo Optimo RTS:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1

Special operation

Depending on the peripherals installed and the operating options set by your installer, the Dexxo Optimo RTS system may perform the following
special operations:
Full opening cycle using Telis or similar remote controls (Fig. 9a)
Partial opening cycle using Telis or similar remote controls (Fig. 9b)
Safety photoelectric cell operation
An obstacle detected between the cells will prevent the door from closing.
The door will stop and then reopen when an obstacle is detected during the close cycle.
The light will flash for 30 seconds during this process.
Pedestrian door safety function
Opening a pedestrian door within the garage door will prevent the door from moving.
The light will flash for30 seconds during this process.
Flashing amber light
The amber light comes on whenever the door moves, with a two second advance warning before the start of door motion.
Working from the back-up battery
If a back-up battery is installed, the Dexxo Optimo RTS motor will operate when a power cut occurs.
The following conditions apply to operation:
Door speed is reduced.
The light will not come on.
The safety devices are disabled.
Battery specifications:
Endurance: the battery will last for 24 hours with a maximum of 5 to 10 operating cycles depending on the weight of the door.
Recharging time: 48 hours.
Service life prior to replacement: approx. three years.
To ensure optimum battery life, we recommend that the power to the motor is switched off and the door is operated for a number of cycles using
battery power (three times a year).
Forced operation mode (Fig. 10)
This function is used to move the door at any time (remote control lost, safety mechanism failure, etc.).
Remove the built-in lighting cover:
Control door motion using the "
Pressing and holding the "
-" button will trigger closure.
Pressing and holding the "
+" button will trigger opening.

Power outage

Following a power outage, the motor must recognise its "fully open" position again.
Open the door fully using a memorised remote control. The door will open at a degraded speed.
Allow the door to open to the "fully open" position.
4
9 b
+" and "-" buttons.
9a
10