Any use of this product outside the scope of application
described in this manual is prohibited (see "Scope of
application" paragraph in the installation manual).
The use of any accessories or components not validated
by Somfy is prohibited - safety of persons won't be
ensured.
Somfy cannot be held liable for damages resulting from non
compliance with the instructions of this manual.
In case of any doubts when installing the motorisation, or
to obtain additional information, consult the website www.
somfy.com.
change to the standards or to the motorisation.

1.3 Preliminary checks

> Installation environment
ATTENTION
Do not spray water onto the motorisation.
Do not install the motorisation in an explosive environment.
> Condition of the door to be motorised
Before installing the motorisation, check that:
- the door is in good mechanical condition
- the door is correctly balanced
- the door can be opened and closed properly using a force
of less than 150 N.
CAUTION: It is dangerous to perform any operation on the
door springs (the door may fall).
Check:
- The door mountings are in good condition.
- The structures of the garage (walls, lintel, partitions,
Strengthen these if necessary.
>
Make sure the parts of the door do not encroach onto the
pavement or public thoroughfare.
must be equipped with a system that prevents it from
moving when the wicket door is not in the safety position.
2
WARNING
DANGER
WARNING

1.4 Electrical installation

The installation of the power supply must comply with the
standards in force in the country in which the motorisation
The electric line must be exclusively reserved for the
motorisation and equipped with protection, comprising:
- a 10 A fuse or breaker,
- a differential type device (30 mA).
An all-pole supply cut-off device must be provided.
(maximum residual voltage 2 kV).
> Cable feed
Underground cables must be equipped with a protective
and the accessories cables.
For overground cables, use a cable grommet that will
withstand the weight of vehicles (ref. 2400484).

1.5 Safety instructions relating to installation

Before installing the motorisation, remove any unnecessary
cords or chains and deactivate any locking device (bolt)
which is not required for motorised operation.
Do not connect the motorisation to a power source (mains,
battery or solar) before installation is complete.
Ensure that any danger zones (crushing, cutting, trapping)
elements caused by the opening movement of the driven
part are avoided or indicated on the installation (see the
section "Danger zones").
to the end-user.
Modifying one of the elements provided in this kit or using
an additional element not recommended in this manual is
strictly prohibited.
Monitor the door as it moves and keep people away from it
until installation is complete.
Do not use adhesive to secure the motorisation.
Install the internal manual back release device at a height
of less than 1.8 m.
release device near to its mobile component.
Take care when using the manual back release device as
an open door can suddenly fall off if the springs are weak,
broken, or incorrectly balanced.
Metro 800 RTS / Metro 1000 RTS
DANGER
WARNING
DANGER
WARNING
WARNING
WARNING