Metro 800 RTS / Metro 1000 RTS
ATTENTION
1.5 m and within sight of the door, but away from moving
parts.
After installation, ensure that:
- the mechanism is correctly adjusted
- the manual back release device is operating correctly
- the motorisation changes direction when the door
encounters an object 50 mm high on the ground.
For operation in automatic mode or remote control,
photoelectric cells must be installed.
For operation in automatic mode, or if the garage door faces
a public road, an orange light type signalling device may be
required to comply with the regulations in the country in
which the motorisation is installed.
> Clothing precautions
Take off any jewellery (bracelet, chain, etc.) during
installation.
For manoeuvring, drilling and welding operations, wear
appropriate protection (special glasses, gloves, ear
protection, etc.).

1.6 Regulations

SOMFY declares that this product
Metro 800 RTS / Metro 1000 RTS
complies with the essential requirements of applicable
European directives.
The full text of the CE declaration of conformity is available
at the following website www.somfy.com/ce.

1.7 Assistance (Wisniowski)

installing your motorisation.
Do not hesitate to contact us; our specialists are on hand to
answer all your questions. Internet: www.wisniowski.pl
After-sales / Hotline :
Tel : +48 18 44 77 111
Fax : +48 18 44 77 110

1.8 Danger zones

Risk prevention - motorisation of sectional/up and
over garage door for residential usage
Zone 4
Zone 5
Zone 3
Zone 4
Copyright © 2016 Somfy SAS. All rights reserved
WARNING
WARNING
Zone 2
Zone 1
Zone 3
Zone 1
Zone 4
Risk zones: measures to be taken to eliminate risks
RISK
ZONE 1
Risk of crushing
between the ground
and the lower edge
of the door during
closing
ZONE 2*
Risk of crushing
between the lintel and
the upper edge of the
door during closing
ZONE 3*
Risk of cutting or
trapping between the
door panels in gaps
of between 8mm and
25mm
ZONE 4*
Risk of trapping
between the roller rails
and bearings
ZONE 5*
Risk of crushing
between the
secondary edges and
* For zones 2, 3, 4 and 5, no protection is required if the
door has continuous control or if the danger zone is more
than 2.5 m above the ground or any other permanent
access level.
Zone 2
Zone 5
SOLUTION
Obstacle detection built into
the motorisation. It must be
imperatively checked that the
obstacle detection complies with
annex A of the standard EN 12
453.
For operation with automatic
closing, install photoelectric cells
(see installation manual)
Obstacle detection built into
the motorisation. It must be
imperatively checked that the
obstacle detection complies with
annex A of the standard EN 12
453.
Eliminate all sticking points and
all sharp edges from the surface
of the door
Eliminate all sharp edges on the
guide rails
between the rails and the
bearings
Obstacle detection built into
the motorisation. It must be
imperatively checked that the
obstacle detection complies with
annex A of the standard EN 12
453.