Section 2
Refrigeration System Installation
Remote Condensing Unit Only
QuietQube®
Ice Machine
Condensing Unit
RNS1000C
RFS1200C
RFS2300C
*Line Set
Suction Line
RC 21/31/51

Important
Manitowoc remote systems are only approved and
warranted as a complete new package. Warranty on the
refrigeration system will be void if a new ice machine
head section is connected to pre-existing (used) tubing
or condensing units or vice versa.

USAGE WITH NON-MANITOWOC CONDENSING UNITS

Manitowoc Remote Condensing Units are specifically
designed for usage with a QuietQube® Ice Machine Head
Section. Standard condensing units and Non-Manitowoc
condensing units are not approved for use with a
QuietQube® Ice Machine Head Section.
,
The 60-month compressor warranty (including the
24-month labor replacement warranty) will not
apply if the Manitowoc Ice Machine and Manitowoc
Remote Condensing Unit are not installed according
to specifications. This warranty also will not apply if
the refrigeration system is modified with a condenser,
heat reclaim device, or other parts or assemblies not
manufactured by Manitowoc Ice.
Part Number 000007644 Rev 01 12/16
Remote
Line Set*
RCU1098
RC-21
RCU1075
RC-31
RCU2375
RC-51
Liquid Line
5/8 inch
3/8 inch
(15.9 mm)
(9.5 mm)
Caution
Factory Equipment Refrigeration Amounts
ICE MACHINE HEAD SECTION
Each ice machine condensing unit ships from the factory
with a R-404A refrigerant charge appropriate for the
entire system operation. The serial tag on the ice machine
indicates the refrigerant charge. The refrigerant charge
is sufficient to operate the ice machine in ambient
temperatures between -20°F (-28.9°C) and 120°F (48.9°C).
With line set lengths of up to 100 feet (30.5 m).
n
Potential Personal Injury Situation
The QuietQube Condensing Unit contains the
refrigerant charge. Installation and brazing of the line
sets must be performed by a properly trained and EPA-
certified refrigeration technician aware of the dangers
of dealing with refrigerant-charged equipment.
,
Never add more than nameplate charge to the
refrigeration system for any application.
REFRIGERATION LINE SETS/TRAP KIT
Refrigeration Rated Tubing and Trap Kits are shipped
capped with atmospheric pressure.
n
Installation of a QuietQube® Condensing Unit may
require the use of special equipment for placement.
Trained and qualified personnel are required for proper
rigging and lifting.
Installation Instructions
Warning
Caution
Warning
15