11. TROUBLESHOOTING GUIDE

PROBLEM
POSSIBLE REASON
The insert gives
Inappropriate use of the insert
off smoke
Smoke duct is cold
Smoke duct is obstructed
Smoke duct is oversized
Smoke duct is tight
The draw is not enough
Smoke duct with infiltrations
More than one equipment connected to the
duct
Air returns
Inappropriate use of the insert
Combustion range too low. Lack of draw
Excessive ash accumulation
The smoke duct does not protrude the top
of the roof
Combustion out of
The door is not sealed properly or is open
control
Excessive draw
Refractory sealing plaster is damaged
Smoke duct is oversized
Strong winds
Green or wet wood with bad quality
Insufficient heat
Green or wet wood with bad quality
Lack of primary air
Smoke duct with air infiltrations
Masonry exterior of the chimney is cold
Heat loss in the house
Low flow in
One of the fans does not work
channel
There are too many channel duct
The connections rings are not correctly placed Check the placement of the connection rings
The fans do not
The thermostat has been blocked
stop even when
the equipment
is cold
The fans do not
The thermostat do not detect the temperature
work in automatic
mode
The fans always
The resistance is faulty
work at the same
speed
The circuit
Faulty components or electrical touches
breaker /
differential switch
stops when the
fan works
** The note PROFES means that the task must be done by a professional.
SOLUTION
Open the primary air intake a few minutes and then open
the door
Pre-heat the insert
Check the duct and the connector to see if it is obstructed
or has excessive soot
Install an appropriate diameter
Install an appropriate diameter
Add length to the chimney
Seal connections between sections
Disconnect the rest of equipments and seal the entrances
Open completely the primary air intake one and, later, the
door during a few minutes
Use the insert with an appropriate range. Increase the
primary air intake
Empty the ash pan frequently
Add length to the chimney
Close the door or change the sealing cords
Check the installation or install a draft-diverter valve
Check the joints and use refractory putty
Install an appropriate diameter
Install an appropriate chimney cowl
Use dry wood. Air dried during at least 1 year
Use dry wood. Air dried during at least 2 years
Increase the primary air intake
Use an insulated system of chimney
Insulate thermally the chimney
Seal windows, openings, etc
Check the correct operation of the fans
Check the longer of the channel
The thermostat is defective and have to be replaced
The thermostat is defective and have to be replaced
The resistance is defective and have to be replaced
Check the components and the state of the electrical
system.
Table 2
43
PROFES
PROFES
PROFES
PROFES
PROFES
PROFES
PROFES
PROFES
PROFES
PROFES
PROFES
PROFES
PROFES
PROFES
PROFES
PROFES
PROFES
PROFES
PROFES
PROFES