IMPORTANT: anticipate the installation of KIT-2 near the wood-burning thermo-stove so that the sensor can
detect in a short preriod of the time the heat coming from the wood-burning thermo-stove. If possible, place
the sensor on the pipes inside the thermo-stove and, if necessary lengthen the connection cable between
the sensor and the regulator. These operations must be made with caution in order to avoid the risk of
electric interference in the sensor cable.
Electronic regulator (see drawing D47). The electronic regulator is preset with all needed parameters
to the performance of a hydraulic system.
Operation:
The diverter valve switch the water flow to the installation when it gets the value established by the user (by
default 45ºC). The water "recirculates" in the exchanger until it reaches a high temperature to give heat to the installation.

13. TROUBLESHOOTING GUIDE

PROBLEM
POSSIBLE REASON
The thermo-
Inappropriate use of the insert
stove gives off
smoke
Smoke duct is cold
Smoke duct is obstructed
Smoke duct is oversized
Smoke duct is tight
The draw is not enough
Smoke duct with infiltrations
More than one equipment connected to the
duct
Air returns
Inappropriate use of the thermo-stove
Combustion range too low. Lack of draw
Excessive ash accumulation
The smoke duct does not protrude the top
of the roof
Combustion out
The door is not sealed properly or is open
of control
Excessive draw
Refractory sealing plaster is damaged
Smoke duct is oversized
Strong winds
Green or wet wood with bad quality
Insufficient heat
Green or wet wood with bad quality
Lack of primary air
Smoke duct with air infiltrations
Masonry exterior of the chimney is cold
Heat loss in the house
** The note PROFES means that the task must be done by a professional.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
SOLUTION
Open the primary air intake a few minutes and then open
the door
Pre-heat the thermo-stove
Check the duct and the connector to see if it is obstructed or
has excessive soot
Install an appropriate diameter
Install an appropriate diameter
Add length to the chimney
Seal connections between sections
Disconnect the rest of equipments and seal the entrances
Open completely the primary air intake and, later, the door
during a few minutes
Use the insert with an appropriate range. Increase the
primary air intake
Empty the ash pan frequently
Add length to the chimney
Close the door or change the sealing cords
Check the installation or install a draft-diverter valve
Check the joints and use refractory putty
Install an appropriate diameter
Install an appropriate chimney cowl
Use dry wood. Air dried during at least 1 year
Use dry wood. Air dried during at least 2 years
Increase the primary air intake
Use an insulated system of chimney
Insulate thermally the chimney
Seal windows, openings, etc
Table 2
35
D47
SET
ON
PROFES
PROFES
PROFES
PROFES
PROFES
PROFES
PROFES
PROFES
PROFES
PROFES
PROFES
PROFES
PROFES