Never use the same chimney for several equipments at the
same time (see drawing D43).
The minimum diameter must be 4 dm2 (for example, 20 x 20 cm) for inserts
with a diameter below 200 mm or 6.25 dm2 (for example, 25 x 25 cm) for
equipments with a diameter higher than 200 mm.
A big section of the chimney (for example, diameter of the pipe superior to
the one recommended) may results in a volume too large to be heated and,
therefore, it can cause difficulties for the proper operation of the equipment.
In order to avoid this problem, it is necessary to enclose the chimney in its
entire length. However, a small section (for example, diameter of the pipe
inferior to the one recommended) may cause a reduction of the draft.
The flue must be away from flammable or combustible materials
through an appropriate insulation or an air chamber. In the case that
they pass through flammable materials compounds, they should be
eliminated.
Inside, it is forbidden that there are pipes of installations or air
abduction channels. It is also prohibited to do mobile or fixed openings for
connecting other different equipments..
If we use metallic pipes inside a masonry duct, it is essential that
they are well insulated and with appropriate materials (insulating fibre
coatings) in order to avoid the deterioration of the masonry or the
interior coating.
D44
(1)
In the case that there are chimneys placed side by side,
one of them must exceed to the other at least 50 cm in order
to avoid pressure movements among them
4.1

CONNECTION OF THE INSERT TO THE CHIMNEY

The connection to the insert for the smoke evacuation must be done with rigid aluminized steel pipes or stainless steel pipes.
It is forbidden the use of flexible metallic pipes or fibre cement pipes because they damage the safety of the connection because they
are subject to jerks and breaks, which causes smoke looses.
The chimney must be fixed hermetical to the smoke outlet of the insert. It should be rectilinear and with a material that supports high
temperatures (minimum 300ºC). It can have a maximum inclination of 45° whereby excessive deposits of condensation produced in the initial
stages of ignition and / or excessive soot formation is avoided. Moreover, it avoids the slowing down of the smoke when it comes out.
The lack of sealing of the connection may cause the malfunction of the equipment.
The internal diameter of the connection pipe should correspond to the external diameter of the chimney of the equipment. This service is
assured by the pipes complying with DIN DIN 1298.
4.2

COATING AND INSTALLATION OF THE INSERT

When the insert is installed in a facing or an old chimney it is essential the space among the top and the sides of the equipment and the
fireproof material of the hood (which block the base of the chimney) will be constantly ventilated. For this reason, it is necessary to keep an
fresh air entry on the bottom of the facing and an exit on the top (hot air exit) by the hood. The function will be improved due to there is a
natural convection circuit. Every one of these openings must be free and not blocked with a surface of 3 dm2 at least (for example, grille 30
x 10 cm.).
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
D43
(1)
The chimney can't have obstacles around 10 m towards
walls or trees. Otherwise, raise it at least 1 m above the
obstacle.
The chimney must exceed the top of the roof at least 1 m.
38