The parameters are described in the following table
SECONDARY MENU PARAMETERS
Temperature Fan Activation
Temperature Fan Activation Hysteresis
ALARM Temperature Activation
SAFETY Temperature Activation
SAFETY FAN Temperature Activation
SAFETY Function Enable
SAFETY FAN Function Enable
STANDBY Function Enable
BUZZER Function Enable
Fan Speed P01
Fan Speed P09
Fan Speed P10
Temperature Range of Regulation for Proportional Modality
P01 / P09 / P10 Speed REGULATION (parameters U01 / U09 / U10)
-
Enter in SECONDARY Menu
-
Select the parameter to verify/modify : the fan works automatically at the set speed
-
Modify the value until the desired value : in this way it is possible to control the speed directly.
-
Memorize by pushing button P4
-
Eventually repeat the operation for the other speeds/parameters
-
To exit, wait about 10 seconds.
Supply:
Protection:
Temperature Probe:
Output:
Dimensions:
Applied Rules:
2.2

SPECIFICATIONS ACCORDING TO THE MODEL

2.2.1

MODEL LONDRES, LONDRES VISION, LONDRES-T AND LONDRES-T VISION

Admission of fresh air
Due to the high power of this models of inserts it is advisable to foresee an air intake coming from outside the room to avoid the overheating
of the equipment.
Isolation of the insert: advantages and drawbacks
Some thermal insulator can be placed between the facing and the insert.
Every way, all cautions must be taken to avoid an overheating of the walls and every constructional elements nearby the equipment (for
instance, wooden beam), and at the moment of the placement these materials will be insulated according to the rules.
Advantages:
-
A lower loss of heat. This is only valid in case of the insert is beside an outer wall. Unless the case the heat will not be lost, it will be
dissipated in the first step by the facing and the to the adjacent rooms.
-
Reduction of temperature in case of flammable elements near the insert.You should always watch the air intakes for the convection
(on the bottom, laterals and rear of the insert) are not obstructed. Ideally, ceramic fibre or Rockwool rigid panels, whose fibres are
agglomerated by some bonding agent, shall be used.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
CODE
MIN
SET
30º
iSt
TAL
100º
TSI
80º
TSA
100º
SIC
0 [off]
SAF
0 [off]
Stb
0 [off]
Enb
0 [off]
U01
00
U09
00
U10
00
DEL
20º
230 Vac ±10%~ 50HZ: EMI filter on side
Internal Fuse
Working Temperature: -50°C / 250 °C
Range of Measure: 0 – 180 °C: ± 1°C
FAN: 230 Vac Imax: 0,8A/1,5A high power version
Inbox Controller 120 x 80 x 50 [mm]
EN 60730-1 50081-1 EN 60730-1 A1 50081-2
29
DEFAULT
MAX
45º
99º
35º
120º
180º
100º
140º
135º
180º
1 [on]
1 [on]
1 [on]
1 [on]
1 [on]
1 [on]
1 [on]
1 [on]
16
100%
70
100%
100
100%
20º
100º
INSERTS