Bronpi KENIA Série Instructions D'installation, D'utilisation Et D'entretien page 29

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 45
External aspect and electrical connections
PRODUCT COMPOSITION
-
Boxed temperature controller 3 module
-
Cover Plate, Inbox box
-
Temperature Probe, Accessories, Instructions
FUNCTIONING
ON/OFF:
The On/Off of the controller is made by pushing the button P1
The state OFF is signaled through the led L1
FUNCTIONING Modality
-
MANUAL: advice signal MAN
The fan is at the set speed independently by the Probe's temperature
-
AUTOMATIC: advice signal AUT
The Fan starts at the set up speed when the trmperature is higher than the setted Thermostat SET
-
PROPORTIONAL: advice signal PROP
The fan changes its speed according to the temperature in the range SET ÷ SET+DEL
STANDBY Function: if parameter Stb =1
If the device is OFF, and the temperature is higher than the value of thermostat TSI
-
The device goes in ON automatically
SAFETY Function: if the parameter SIC = 1
If the probe's temperature is higher than value of thermostat TSI
And the fan is OFF in MANUAL Modality
-
The device goes automatically in the Proportional Modality waiting 10 seconds.
SAFETY FAN Function: if the parameter SAF = 1
If the probe's temperature is higher than value of thermostat TSA
-
The Fan is OFF
ALARM Function:
If probe's temperature is higher than the value of thermostat TAL and the parameter Enb = 1
-
The acoustic signal is activated
-
This signaling can be deactivated for 5 minutes by pushing a button
-
After 5 minutes, if there's again the condition of alarm, it is activated again.
MAIN MENU
FUNCTIONING Modality Selection
-
Press P4 key to see the current modality: it's signaled by the display and the led
-
Pressing again the P4 key, you can select cyclically one of three functioning modality MAN, AUT, PRP signaled on the display and by
the specific led.
-
The setting is automatically memorized after 4 seconds
-
The L5 shows the status of the Fan
SPEED Selection
-
Pressing P2 or P3 keys the setting of the current fan speed is visualized or modified
-
P0= Off (only in Manual); P1 = Minimum Speed; P10= Maximum Speed
-
This function is not available in the PROPORTIONAL Modality
-
In the AUTOMATIC Modality the speeds that can be set are P1 ÷ P10
FAILURE OR ALARM SIGNALS
The controller can signal the failure of the probe blinking message for the failure signal:
-
Lo: indicates a low temperature (temperature under 0°C):Probe Open or Disconnected
-
Hi: indicates a high temperature (temperature over 180°C):Probe in Short Circuit
ATTENTION
-
Avoid join together the probe's cables with power's cables.
-
Provide the system's feeding with a bipolar switch according to the actual rules and with opening distance of the contacts of at least 3
mm for each pole.
-
Installation and the electrical connection of the device have to be made by experienced personal and with appropriate equipping.
-
Before the connection be aware that the electrical feeding is not connected.
SECONDARY MENU
It allows to modify the functioning parameters of the controller.
-
To enter the MENU push together buttons P2 and P3 for about 5 seconds.
-
To scroll the code list use the button P2 or P3
-
To show the parameter's value push the button P4
-
To modify the parameter's value push the buttons P2 or P3
-
To visualize again the code list and memorize push the button P4
-
To exit and memorize wait for about 10 seconds.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
28
INSERTS

Publicité

Table des Matières
loading

Table des Matières