Londres-T Visión And Panamá Series Central Unit - Bronpi KENIA Série Instructions D'installation, D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 45
Barbecue grill
The barbecue grill is an accessory that incorporates the models of the series Paris. It is
adjustable in two heights depending on the slot of the lateral guide used. To prevent its
deterioration, it is advisable to remove it when not in use (see drawing D17).
Forced ventilation
D18
These three-positions have the following functions:
-
0 position: the fans are turned off when there is no combustion inside
the chamber due to the stove is provided with a thermostat that
controls the fan according to the temperature of the insert.
-
1 position: the fans run in a low speed.
-
2 position: the fans run in a high speed.
The models of the Paris series lack thermostat. Therefore, the ignition and
regulation is made by the switch and allows the possibility of disconnecting
the turbine (position 0), even with combustion in the equipment. In the same
way, if you want the turbine to operate, you must place the switch in position
1 (slow speed) or 2 (fast speed).
Connection
In the right side of the insert you will find the cable that connects
to the network. It is mandatory to not cut it in the entire length
because this section is useful when changes in the electrical
components are needed.
It is obligated the correct connection of the installation to earth connection.
The installation of the system might be done by skilled labour and qualified under the current rules.
WARNING!!
The insert (except Paris Series) must be always connected to electrical network in order to, in
case of a high temperature, fans could start and dissipate the heat to the room where it is installed
or to any other adjacent room. The insert must never be unplugged from the network when it is
burning. In this case, the warranty of the insert shall terminate.
The inserts are provided with connections for two ventilation additional outputs.
To install them, follow the next steps:
a.
Remove the close covers of the air outputs placed at the high of the sump.
b.
Set the connection collars on the hole or holes.
c.
Drill the wall or existent hood to pass and install the fireproof flexible tubes (diameter of 12 cm)
with their corresponding connection.
d.
Set the tubes with metallic clamps to the corresponding collars and grilles. Each pipe must not
exceed recommended channelling length and it must be insulated with insulated materials to
avoid noises and loss of heat.
e.
The grilles must be placed higher than 2 meters over the floor to avoid the heat air annoy the
people.
2.1
LONDRES-T VISIÓN AND PANAMÁ SERIES CENTRAL UNIT
L1
OFF
P1
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
Some inserts are provided with axial fans of 160 m
adequate to improve the heat distribution by the ventilation of the
room or the room beside.
However, the models Panamá E and F include a tangential turbine
of 680 m3/h, while the Londres models can optionally have the
tangential turbine of 680 m
/h. These are called Londres-T.
3
The models of the Paris series incorporate as standard a tangential turbine can be of 225, 290 or 335 m
according to the measurement of the model.
The operation of the turbine of the models Panamá and Londres-T is explained in section 2.1.
In models with fans the start and the control of the ventilation is made by the three-position switch placed on the
right bottom side(see drawing D18).
L2
MAN
L3
AUTO
PROP
L4
L5
MENU
P2
P3
P4
/h each one,
3
CONNECTION TO
GROUND
INSTALLATION SUPPORT
CHASSIS OF THE
CONNECTION
TO GROUND
LINEA VENT.
230 Vac 230 Vac
27
/ h,
3
220 V
L
N
FANS
THERMOSTAT
R 820 ohm
50 W
COMMUTADOR 2
POSITIONS
SONDA
FUSE
INSERTS
D17

Publicité

Table des Matières
loading

Table des Matières