4 OPERATION

The operation of the 8025 is classified according to three levels.
Display
This menu displays flow, output current, main totalizer and daily totalizer. The daily totalizer
can also be reset in this menu.
Parameter Definition
All the necessary settings, such as the language, engineering units, K-Factor, 4...20 mA
measuring range, pulse output, relay and filter are carried through in this menu.
Here, the main, as well as the daily totalizer are simultaneously reset.
Testing
A flow can be simulated in this menu, which allows to test a process in the "dry-run
condition".
This menu also displays the sensor frequency and allows to change the basic settings
(Offset, Span) of the device.

4.1 Transmitter Operating and Control Elements

Choice of digit value
Steps from 0 to 9
Direction downwards
in menu or sideways
for digit selection
FLOW TRANSMITTER 8025
E-22-
Accept of choosen
parameter or adjusted
value
(Relay 2: contact closed)
(Relay 1: contact closed)
8025 - 8025RR