Télécharger Imprimer la page

Enraf Nonius Endomed 482 Mode D'emploi page 43

Masquer les pouces Voir aussi pour Endomed 482:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 73
Hold time:
Select
with button [12] and adjust its value with the central controller [16];
Ramp down time:
Select
with button [12] and adjust its value with the central controller [16];
Interval time:
Select
with button [12] and adjust its value with the central controller [16];
Delay time (only available with linked channels):
Push button [13] and select channel 2 with the central controller [16].
Select
with button [12] and adjust its value with the central controller [16];
Select CC or CV with button [13] and the central controller [16];
Polarity:
Select
or
with button [13] and the central controller [16];
Select the desired channel with button [13] and the central controller [16]. Adjust the current intensity
with controller [17];
Push button [14] to start the therapy in case a surge program was selected.
5.2.2.5 Microcurrent
Push button [7] to select
channels;
Push button [8], select
Frequency:
Select
(Hz or kHz) with button [9] and adjust its value with the central controller [16];
Alternating or not alternating:
Select
or
with button [9] and the central controller [16];
Treatment time:
Select
with button [12] and adjust its value with the central controller [16];
Alternation sequence (only with
Ramp up time:
Select
with button [12] and adjust its value with the central controller [16];
Hold time:
Select
with button [12] and adjust its value with the central controller [16];
Ramp down time:
Select
with button [12] and adjust its value with the central controller [16];
Surge program (only with
Ramp up time:
Select
with button [12] and adjust its value with the central controller [16];
Hold time:
Select
with button [12] and adjust its value with the central controller [16];
Ramp down time:
Select
with button [12] and adjust its value with the central controller [16];
Interval time:
Select
with button [12] and adjust its value with the central controller [16];
Delay time (only available with linked channels):
Push button [13] and select channel 2 with the central controller [16].
Select
with button [12] and adjust its value with the central controller [16];
Polarity (only with
Select
or
with button [13] and the central controller [16];
Select the desired channel with button [13] and the central controller [16]. Adjust the current intensity
with controller [17];
Push button [14] to start the therapy in case a surge program was selected.
5.2.2.6 High voltage
Push button [7] to select
channels;
Push button [8], select
Alternating or not alternating:
Select
or
with button [9] and the central controller [16];
Beat frequency:
Select
with button [10] and adjust its value with the central controller [16];
Modulation frequency (spectrum):
Select
(%) with button [10] and adjust its value with the central controller [16];
Modulation time (spectrum):
Select
with button [11] and adjust its value with the central controller [16];
Treatment time:
. Use the central controller [16] to select the desired channel or to link the
with the central controller [16] and press button [14] to accept;
selected):
selected):
selected):
. Use the central controller [16] to select the desired channel or to link the
with the central controller [16] and press button [14] to accept;
GB