Select
with button [12] and adjust its value with the central controller [16];
Interval time:
Select
Delay time (only available with linked channels):
Push button [13] and select channel 2 with the central controller [16].
Select
Select CC or CV with button [13] and the central controller [16];
Select the desired channel with button [13] and the central controller [16]. Adjust the current intensity
with controller [17];
Push button [14] to start the therapy in case a surge program was selected.
5.2.2.3 Asymmetrical and Symmetrical biphasic pulsed current (TENS)
Push button [7] to select
channels;
Push button [8], select
Pulse width:
Select
Beat frequency:
Select
Make your choice between frequency modulation and burst mode as these two options are mutually
exclusive;
If frequency modulation is desired:
First check burst mode to be off:
Select
Modulation frequency (spectrum):
Select
Modulation time (Spectrum):
Select
with button [11] and adjust its value with the central controller [16];
If burst mode is desired:
First check frequency modulation to be off:
Select
Burst frequency:
Select
Treatment time:
Select
with button [12] and adjust its value with the central controller [16];
Surge program (when desired):
Ramp up time:
Select
with button [12] and adjust its value with the central controller [16];
Hold time:
Select
with button [12] and adjust its value with the central controller [16];
Ramp down time:
Select
with button [12] and adjust its value with the central controller [16];
Interval time:
Select
Delay time (only available with linked channels):
Push button [13] and select channel 2 with the central controller [16].
Select
Select CC or CV with button [13] and the central controller [16];
Select the desired channel with button [13] and the central controller [16]. Adjust the current intensity
with controller [17];
Push button [14] to start the therapy in case a surge program was selected.
5.2.2.4 Monophasic rectangular –and triangular pulsed current
Push button [7] to select
channels;
Push button [8], select
Pulse width:
Select
Pulse interval:
Select
Treatment time:
Select
with button [12] and adjust its value with the central controller [16];
GB
Surge program (when desired):
8
Ramp up time:
Select
with button [12] and adjust its value with the central controller [16];
with button [12] and adjust its value with the central controller [16];
with button [12] and adjust its value with the central controller [16];
. Use the central controller [16] to select the desired channel or to link the
or
with the central controller [16] and press button [14] to accept;
with button [9] and adjust its value with the central controller [16];
with button [10] and adjust its value with the central controller [16];
with button [11] and set its value to zero with the central controller [16];
with button [10] and adjust its value with the central controller [16];
with button [10] and set its value to zero with the central controller [16];
with button [11] and adjust its value with the central controller [16];
with button [12] and adjust its value with the central controller [16];
with button [12] and adjust its value with the central controller [16];
. Use the central controller [16] to select the desired channel or to link the
or
with button [9] and adjust its value with the central controller [16];
with button [10] and adjust its value with the central controller [16];
with the central controller [16] and press button [14] to accept;