2.5
Electromagnetic interference
Simultaneous connection of a patient to HF surgical equipment and an electrical stimulator must not be
done as this may result in burns at the site of the stimulator electrodes. Therefore, simultaneous
connection is not allowed.
For more information see chapter 4, Installation.
2.6
Limitations of liability
To the maximum extent permitted by applicable law, in no event will Enraf-Nonius or its suppliers or
resellers be liable for any indirect, special, incidental or consequential damages arising from the use of or
inability to use the product, including, without limitation, damages for loss of goodwill, work and
productivity, computer failure or malfunction, or any and all other commercial damages or losses, even if
advised of the possibility thereof, and regardless of the legal or equitable theory (contract, tort or
otherwise) upon which the claim is based. In any case, Enraf-Nonius's entire liability under any provision
of this agreement shall not exceed in the aggregate the sum of the fees paid for this product and fees for
support of the product received by Enraf-Nonius under a separate support agreement (if any), with the
exception of death or personal injury caused by the negligence of Enraf-Nonius to the extent applicable
law prohibits the limitation of damages in such cases.
Enraf-Nonius can not be held liable for any consequence resulting from incorrect information provided by
it's personnel, or errors incorporated in this manual and / or other accompanying documentation
(including commercial documentation)
The opposing party (product's user or it's representative) shall disclaim Enraf-Nonius from all claims
arising from third parties, whatever nature or whatever relationship to the opposing party.
3 Indications and Contra-Indications
Please refer to the optional therapy books.
3.1
Indications
3.1.1
Electro therapy
Diagnostics, electropalpation for:
pain points;
trigger points;
hyperaesthetic regions;
motor trigger points;
S/d curve
Therapy:
A. Pain control in:
pain points;
trigger points;
hyperaesthetic regions.
B. Autonomic disorders such as:
shoulder/hand syndrome;
Raynaud's disease;
Buerger's disease;
Sudeck's dystrophy;
neurological diseases;
myalgia.
C Muscle stimulation:
for restoration of kinaesthesia;
for treatment of atrophy;
for stimulation of the internal and external sphincters in the treatment of urinary incon-tinence;
revalidation;
muscle strengthening (sport);
neurological conditions.
GB
2
D. Iontophoresis.

Publicité