[6] Mains adapter indicator
This lamp indicates that the mains adapter is connected to the power supply.
[7]Therapy options
Selection button for electrotherapy, current channel selection, linked current channels, interval
between program steps.
[8] Selection button current waveform
This button is to select the different current waveforms.
[9] Selection button for:
Carrier wave, pulse width, microcurrent frequency, interferential current type, alternating mode (High
Voltage and Microcurrent).
[10]
Selection button for:
Beat frequency, phase interval, burst frequency (Russian stimulation), vector position, balance
position, Diadynamic current waveforms and modulation frequency (spectrum).
[11]
Selection button for:
Modulation time (spectrum), duty cycle (Russian stimulation), burst frequency (TENS) and treatment
step number (protocols)
[12]
Selection button for:
Surge programme, vector rotation time and treatment timer
[13]
Selection button for:
Current channel, CC/CV mode and polarity.
[12]+[13] Emergency stop.
Pressing buttons [12] and [13] simultaneously will terminate all active treatments.
[14] Accept button
To accept the current waveform selection, the pre-programmed protocols and to start the surge
programs.
[15]
Memory button
To generate the memory functions and to recall and store programs
[16]
Central controller
Controller to adjust all settings and parameters.
[17]
Intensity controller
Controller to adjust the current intensity in channel 1 and 2. In 4-pole mode (interferential currents) this
controller adjusts the intensity in both channels together.
[19]
Interval symbol
The symbol
indicates the interval between two program steps of a sequential program.
5.2
Operating the apparatus
5.2.1
Introduction
5.2.1.1 Switch on the apparatus
Turn the apparatus on with switch [1]. The apparatus executes a self test, checking all important functions
and presents itself with the start up settings. The start up settings are adjustable at memory location 0. To
personalise the start up settings, refer to chapter 5.4, Memory Functions.
5.2.1.2 Therapy and channel selection
The Endomed 482 is equipped with two electrotherapy channels. These channels can be used
independently, each channel offering its own set of parameters and treatment timer. It is also possible to
link channels. Use button [7] to differentiate between the basic therapy functions Electrotherapy use the
central controller [16] to select or link channels. The following selections are available:
electrotherapy on current channel 1
electrotherapy on current channel 2
electrotherapy on linked channels
GB