ERROR MESSAGE
105
Nozzles movement
error
E
N
G
L
106 Sugar/stirrer
I
dispenser
S
H
110
Delivery time-out
(selections with
espresso)
114
Cup dispenser with
photocell error
115
Probe temperature.
116
Communication error
117
Delivery time-out
(selections with hot
instant beverages)
118
Error on air break
micro
119
Cup delivery micro
130
Payment system out
of service.
SUB-
CAUSE OF THE ERROR
CODE
1
The nozzles are unable to
complete the reset cycle
when the machine is
restarted
2
Incorrect microswitch
movement when dispensing
position is reached
3
The nozzles are unable to
reach the dispensing
position
4
The nozzles are unable to
return to the home position
5
Incorrect microswitch
movement when returning
to the home position
1
The device is blocked in
its home position
2
The device is activated but
is unable to return to its
home position
3
Incorrect microswitch
movement
The impulse time counted
by the volumetric meter
exceeds the time-out
Cup not detected
The machine has detected
a boiler temperature fault
39
No communication with the
Snack & Food slave
1
The impulse time counted
by the volumetric meter
2
exceeds the time-out.
3
4
During dispensing, no water
is requested
The cup release motor
hasn't completed the
rotation
illycaffè S.p.A. - Via Flavia 110 - 34147 Trieste - Italy -
FAS 400T MPS.M - ISSUE 01
SOLUTION
Remove any possible obstacles.
Remove any possible dirt from inside the
assembly.
Make sure the nozzle microswitch (CDB) is
working properly.
Make sure the nozzle movement gearmotor
(MTBC) is working properly.
 Remove any sugar residue from inside
the sugar dispenser
 Make sure the stirrer dispenser
microswitch (CDZP) is working
properly.
 Make sure the sugar stirrer gearmotor
(MTZP) is working properly.
Check the fan.
Clean the coffee unit filters, as they are
clogged.
Check the water pump is working properly.
The coffee solenoid valve does not open, or
is clogged.
Check the photocell and reflector are
correctly assembled.
Check the cup photocell input switches
correctly.
Check the probe temperature.
Make sure the boiler safety thermostat has
not been triggered
Check the connection cable
Check the master and slave boards are
working properly
Check the fan.
Check the water pump.
The solenoid valve indicated by the sub-
code does not open.
Check the air-break microswitch is working
properly, and that the float is not jammed
Check the cup delivery microswitch (CMB)
is working properly
Check the correct operation of the cup
release gear motor (MS)
Payment
system
disconnected,
powered, or faulty
www.illy.com