6. At the end of the spin, change the position of the calibration weight on the swinging
unit bell as indicated in figure 24.
7. Perform a third spin. This last calibration phase includes the execution of three con-
secutive spins in automatic mode.
At the end of the spin(the message "End CAL" will appear on the display), if the cali-
bration has been successful, an acoustic consent signal goes off at the end of the spin
otherwise the message E 2 is temporarily displayed.
NOTES
- Once the procedure is finished, remove the calibration weight.
- Pressing the key
- THIS CALIBRATION IS VALID FOR ANY TYPE OF WHEEL!
17. EXTERNAL MECHANICAL SENSOR
CALIBRATION (IF INSTALLED)
This programme is used to calibrate the width sensor potentiometer. It must be performed
when the machine requests it by displaying the E4 message, or when the measured and
the actual rim widths differ.
Proceed as follows to recall this programme:
• press the
key
• use the
EM 9250 CompactLine Operator's manual
23
, it is possible to interrupt the programme at any time.
keys to search for GAU CAL
24
UK
113