15.5. AUTOMATIC POSITION SEARCH

When the automatic position search programme is activated, the machine stops the wheel
in the position for application of the outer side weight at the end of every balancing spin;
if it is equal to zero, the wheel is stopped in the inner side weight application position.
Press the
and
tion with the guard raised.
Proceed as follows to deactivate the automatic position search programme:
- press the
- use the
- press the
- use the
- press the
or rPA on
to enable the automatic position search programme
or rPA oFF
to disable the automatic position search programme
- press the
key to confirm and exit.

15.6. SET UP - WARNING OPT

The machine indicates the need to perform an unbalance optimisation procedure (OPT)
with the flashing LED on the display panel.
Proceed as follows to disable this function:
- press the
key
- use the
- press the
key to confirm
EM 9250 CompactLine Operator's manual
(RPA)
keys simultaneously to search for the second side posi-
key
keys to search for SEt UP
key to confirm
keys to search for rPA on (rPA oFF if previously set)
key to change the setting:
keys to search for SEt UP