Potential Complications - MedComp ARCH-FLO Instructions D'utilisation

Cathéter périphérique
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17
The patient's body size is insufficient to accommodate the size
of the implanted device.
The patient is known or is suspected to be allergic to materials
contained in the device.
Past irradiation of prospective insertion site.
Local tissue factors will prevent proper device stabilization and/
or access.

POTENTIAL COMPLICATIONS:

Air Embolism
Aseptic mechanical phlebitis
Brachial Plexus Injury
Catheter occlusion
Cellulitis
Damage/Fracture of catheter
Drainage from insertion site
Exit site infection
Extravasation
Hematoma
Malposition/Migration
Perforation of the vessel
Sepsis
Subcutaneous hematoma
Thromboembolism
Thrombosis
Before attempting the insertion, ensure that you are familiar
with the common and potential complications and their
emergency treatment should any of them occur.
WARNINGS:
Therapies not appropriate for midline catheters include those
therapies requiring central venous access. Refer to standards of
practice and institutional policies.
In the rare event that a hub or connector separates from any
component during insertion or use, take all necessary steps and
precautions to prevent blood loss or air embolism and remove
the catheter.
Do not advance the guidewire or catheter if unusual resistance
is encountered.
Do not insert or withdraw the guidewire forcibly from any
component. The wire may break or unravel. If the guidewire
becomes damaged, the introducer needle or sheath/dilator and
guidewire must be removed together.
Federal Law (USA) restricts this device to sale by or on the order
of a physician.
This catheter is for Single Use Only.
Do not resterilize the catheter or accessories by any method.
Re-use may lead to infection or illness/injury.
The manufacturer shall not be liable for any damages caused by
re-use or resterilization of this catheter or accessories.
Contents sterile and non-pyrogenic in unopened, undamaged
package. STERILIZED BY ETHYLENE OXIDE
Do not use catheter or accessories if package is opened or
damaged.
Do not use catheter or accessories if any sign of product
damage is visible.
CATHETER PRECAUTIONS:
Small syringes will generate excessive pressure and may
damage the catheter. The use of 10cc or larger syringes are
recommended.
Do not trim catheter.
2
-2-
STERILE EO