4.3 Connection of the Ethernet
cable
The Ethernet cable shield must always be
earthed via the connector. Always use a
shielded RJ45 connector.
Use of Ethernet cables with the following
characteristics is highly recommended:
• STP (shielded)
• Category 5E (or higher)
The product can be directly connected to an Ethernet
switch.
Carry out the connections as described in the table
(according to the standard specifications: TIA/EIA-
568-B).

CONNECTION OF THE ETHERNET CABLE

Pin number
Cable color
1
Orange-White
2
Orange
3
Green-White
4
Blue
5
Blue-White
6
Green
7
Brown-White
8
Brown
Tab. 2
The example below shows a typical installation.
Personal
Computer
Fig. 1
MNVCMVXHDCAM_1813_EN

4.4 Signal cable connection

SIGNAL CABLE CONNECTION
Colour
White
Yellow
Pink
Violet (blue, cable
tail version)
Red (brown, cable
tail version)
Green
Grey
Tab. 3

4.4.1 Alarm and relay connections

The unit is equipped with the alarms and relays
indicated in the table (Tab. 3, page 7).
Switch
CAUTION! TNV-1 installation type. The
installation is type TNV-1, do not connect it
to SELV circuits.
Function
RS-485 A (+)
RS-485 B (-)
Relay 1, Terminal A
Relay 1, Terminal B
Alarm/Digital input
GND/Common alarm
Reset
The external relay and alarm cable shield
must be earthed.