To increase the effectiveness of the inflation jets, always liberally lubricate beads
and raise the lower bead while activating inflation jets.
To improvethe operation of the tubeless tyre inflation system the compressed air
line pressure must be between 8/10 bar.
Step down on the pedal to inflate tire and seal beads with inflation hose. Frequently
stop to check bead seating pressure gauge.
Explosion hazard. Do not exceed the manufacturer's maximum pressure as stated
on the sidewall of the tyre when seating beads.
If tires being mounted require more than the tire manufacturer's maximum bead
seating pressure and , the wheel should be removed from the tire changer, placed
in an inflation cage, and inflated per manufacturer's instructions.
Reinstall valve stem core into the valve stem after beads have been seated, and then
inflate tire to vehicle manufacturer recommended pressure.
Activate air inflation jets only when sealing the bead. Do not point jets towards people.
Bleed air pressure from system before disconnecting supply line or other pneumatic
components. Air is stored in a reservoir for operation of inflation jets.
Only activate the air inflation jets if the rim securing device is locked in place and
the tire is properly clamped.
ESPLOSION HAZARD. Never mount a tire to a rim that is not the same diameter
(e.g., 16 1/2 inch tire mounting on a 16 inch rim).