Télécharger Imprimer la page

Mondolfo Ferro AS944TI Manuel D'utilisation page 16

Masquer les pouces Voir aussi pour AS944TI:

Publicité

Les langues disponibles

Les langues disponibles

Before making the electrical and pneumatic hook-ups,
make sure that the machine is configured as described
below:
- pedals A and B (if present) in fully depressed
position.
- column C vertical (not tilted).
1.2.d TECHNICAL DATA
- Turntable clamping capacity
- internal clamping .................................................................................................... from 13"
- external clamping ........................................................................................ from 10" to 24"
- Rim width ........................................................................................................ from 3.5" to 14"
- Maximum tire diameter ................................................................................... 1040 mm (41")
- Maximum tire width ........................................................................................... 360 mm (14")
- Bead breaker aperture: ................................................................... from 45 mm to 300 mm
- Bead breaking force ...............................................................................15000 N (pressure 10 bar)
- Operating pressure ...................................................................................................8 - 10 bar
- Air operating flow ...............................................................................187 Nl/min (minimum)
- Power supply voltage .................................................................................. see table below
- Weight ............................................................................................................................. 288 Kg
- Noise levels in operating conditions .................................................................< 70 dB (A)
The noise levels indicated correspond to emission levels and do not necessarily represent safe
operating levels. Although there is a relationship between emission levels and exposure levels,
this cannot be used reliably to establish whether or not further precautions are necessary. The
factors which determine the level of exposure to which the operator is subject to include the
duration of the exposure, the characteristics of the workplace, other sources of noise, etc. The
permitted exposure levels may also vary according to the country. However, this information
will enable machine users to make a more accurate assessment of hazards and risks.
16
DANGER
B
A
AS 944 TI User Manual
C

Publicité

loading