Télécharger Imprimer la page

Klafs 18029 Manuel De Service page 53

Publicité

Les langues disponibles

Les langues disponibles

Sauna/SANARIUM
10.
Maintenance
10.5. Klafs Evaporator EL2: Removing/installing the outlet
valve
Caution!
Before starting maintenance work, decommission the Klafs Evaporator EL2 and make
sure that it cannot be switched on again.
3
Removing the outlet valve
'
The steam cylinder must be removed before you can remove the outlet valve - see page 49.
1.
Pull the wire (1) off the outlet valve.
.
The polarity of the wires is irrelevant.
2.
Release the hose clamp (2) and pull off the filling hose.
3.
Unscrew the two fastening screws (3) with a suitable screwdriver and remove the outlet valve.
4.
Disassemble the outlet valve.
Installing the outlet valve
1.
Install the outlet valve in reverse order.
.
Check the O-rings for damage and replace if necessary before reassembling the outlet valve.
50701290/12.14
EL2 4 230V1
4
2
EL2 8 400V3
1
PAGE 53

Publicité

loading

Ce manuel est également adapté pour:

1803318040