8.
If something does not work
8.1.
Error messages on the display
Risk of injury and damage to property
Repairs and maintenance must only be carried out by Klafs service engineers or by
technicians expressly authorised by Klafs.
Klafs can only provide repairs and servicing work under warranty if this work is carried
out by Klafs service engineers.
Error messages
The Service symbol (1) appears together with the
error message number (2) (e.g. 97).
The controller may still be operational while the
Service symbol is flashing, depending on the
nature of the fault.
No.
Fault
.
)* Applies to SANARIUM controller 18033 and 18040.
.
)* Does not apply to Sauna controller 18029 and 18040.
69
The basic heat sensor in the InfraPLUS heater
is missing or defective.
70
The main temperature sensors in the InfraPLUS
heater are missing or defective.
72
A sauna heater cover was detected.
The cabin door was opened during the
heat-up phase.
90 )* Low water level in the evaporator.
91
Safety-contact switch (SCS) has tripped.
PAGE 30
Sauna/SANARIUM
How to rectify the fault
Stop using InfraPLUS mode.
'
Contact Klafs service engineers.
Check the sauna heater and remove any
objects. Check the service menu point 34
setting.
Close the cabin door.
.
The controller switches off after flashing
20 times.
1.
Top up the evaporator.
2.
Switch the main switch off and on again
to reset the error message.
Remove the object from the grille above the
sauna heater.
Check whether the grille has been removed.
Fit the grille in place, if necessary.