9.
System/equipment faults
Warning
Code
Fault
---
---
---
---
---
---
---
---
---
---
Error
Code
Fault
E1
EL2 card missing.
E2
EL2 card is empty.
E2
EL2 card is
defective.
E2
EL2 card is not
compatible.
E10
Hardware fault.
System faults
Cause
No EL2 card used in the control electronics.
No data on EL2 card.
Invalid data on the EL2 card.
The inserted EL2 card is incompatible with
the hardware or the basic settings on the
control electronics.
Control PCB defective.
Remedy
Insert EL2 card or start test run.
Insert new EL2 card.
Insert new EL2 card.
Insert the correct EL2 card.
Have your Condair service engineer adjust
the basic settings if necessary.
Replace control PCB.