8.
If something does not work
8.2.
Other possible errors
Fault
.
)* Applies to SANARIUM controller 18033 and 18040.
.
)* Does not apply to Sauna controller 18029 and 18040.
)*
LED on the
humidity sensor
flashes, the cloud
symbol in the
controller display
flashes.
(SANARIUM M, B,
S).
)*
There is no steam
escaping
(SANARIUM M, B,
C).
)*
Yellow or red LED
on the evaporator
lights up
(SANARIUM S).
.
Only with
evaporator S with
Birmingham scent
dispenser:
)*
Scent is not being
released
(SANARIUM S).
PAGE 32
Cause
There is no water.
Line break.
Defective heating rod.
Steam cylinder is worn out.
Intake pump defective.
Drain pump defective.
The scent container is empty. Replace the scent container.
The scent pump does not
work or is defective.
The feed hose in the pump is
defective.
The scent line is clogged or
defective.
The scent inlet at the T-piece
to the evaporator tube is
clogged.
Sauna/SANARIUM
Remedy
Fill the evaporator with water.
'
See operating instructions.
'
Contact Klafs service engineers.
'
Contact Klafs service engineers.
'
See operating instructions.
'
Contact Klafs service engineers.
'
See page 47.
Check the scent line from the pump to the
evaporator tube.
Replace the defective scent line.
Check the scent line to the evaporator tube.
Clean the scent inlet at the T-piece to the
evaporator tube.
'
See operating instructions.
Continued on the next page