Télécharger Imprimer la page

Klafs 18029 Manuel De Service page 46

Publicité

Les langues disponibles

Les langues disponibles

9.
System/equipment faults
Warning
Code
Fault
W27
Foam detection.
W28
Steam cylinder
service is due.
W29
Steam cylinder
service is due.
W36
Standby cylinder
draining active.
W37
Enforced draining
active.
Error
Code
Fault
E27
Foam detection (4
autom. drainings
within 24 hours).
E28
Steam cylinder is
worn out.
E29
Steam cylinder
reached max.
operating hours.
---
---
---
---
Equipment faults
Cause
Cause
Foam forming in steam cylinder.
Deposits from hard water and/or electrode
wear.
Steam cylinder reached max. number of
operating hours.
Automatic standby cylinder draining running. No action required.
The automatically enforced cylinder draining
is running.
Remedy
Remedy
Drain the steam cylinder via the drain button
(several times if necessary).
Check the quality of the water supply.
Steam cylinder type A: Replace
Steam cylinder type D: Clean
Reset the service display after replacing or
cleaning the steam cylinder.
'
See page 41.
Steam cylinder type A: Replace
Steam cylinder type D: Clean
Reset the service display after replacing or
cleaning the steam cylinder.
'
See page 41.
No action required.

Publicité

loading

Ce manuel est également adapté pour:

1803318040