Télécharger Imprimer la page

Klafs 18029 Manuel De Service page 38

Publicité

Les langues disponibles

Les langues disponibles

8.
If something does not work
8.4.
Information on troubleshooting the Klafs Evaporator EL2
Important:
Decommission the Klafs Evaporator EL2 before troubleshooting.
Caution!
Repairs must only be carried out by authorised qualified engineers.
When a fault occurs, the controller checks whether the fault is temporary and whether it
can rectify it itself by implementing appropriate measures.
These kinds of faults are not displayed in standard operation mode. However, a
corresponding fault code is generated with the status "Warning".
.
Notice: If the cause of the fault rectifies itself or if the controller rectifies the fault,
the fault is automatically reset.
If the controller fails to rectify the fault even after several attempts (number of attempts
depends on the type of fault) or if the fault will not allow operation to continue, the
power supply to the heater is interrupted by the main contactor and the red LED lights
up in standard operation mode. At the same time, a corresponding fault code is
generated with the status "Error".
8.5.
Calling up fault analysis (info mode)
1.
Press the drain/info button for at least three seconds until the yellow or red LED starts flashing
intermittently.
.
In info mode, the number of times the red LED flashes indicates the first digit and the number of
times the yellow LED flashes indicates the second digit of the fault code.
.
Exiting info mode:
Info mode is automatically cancelled after five minutes.
By pressing the drain/info button.
Display in standard
operation mode
Display in info mode
Steam output
Fault code
PAGE 38
Example
green LED lights up
red LED lights up
green LED flashing
red LED flashing
yellow LED flashing
Sauna/SANARIUM
no
yes
no
no
---
5x
---
---
---
---
0%
50%
---
---
yes
no
no
yes
8x
---
3x
2x
6x
1x
80%
0%
W36
E21
50701290/12.14

Publicité

loading

Ce manuel est également adapté pour:

1803318040