No.
Fault
.
)* Applies to SANARIUM controller 18033 and 18040.
.
)* Does not apply to Sauna controller 18029 and 18040.
92 )* SANARIUM M, S: Maintenance required,
decalcify the evaporator.
.
If the water hardness is set to 0 °dH, the
error message 92 will not appear.
'
See page 14.
SANARIUM B, S: Maintenance required,
decalcify the evaporator.
.
If the water hardness is set to 0 °dH, the
error message 92 will not appear.
'
See page 14.
SANARIUM S: Maintenance required.
.
If the water hardness is set to 0 °dH, the
error message 92 will not appear.
'
See page 14.
93 )* Humidity too low.
94 )* Humidity too high.
95
Line break in the actual temperature sensor.
96
Line break in the heater temperature sensor.
97
The safety temperature limiter (STL) is
interrupted.
98
Short circuit in the actual temperature sensor.
99
Short circuit in the heater temperature sensor.
50701290/12.14
How to rectify the fault
Service the evaporator.
'
See operating instructions.
Service the evaporator.
'
When servicing the evaporator, please
observe the enclosed servicing
instructions for the EL2 evaporator.
Switch the controller off at the mains.
Do not use the sauna cabin.
'
Contact Klafs service engineers.