Télécharger Imprimer la page

Kessel Aqualift F Guide D'installation Et De Maintenance page 54

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 89
A standard plastic pipe muff can be pushed over the connec-
ting piece (see Fig. C).
Alternatively, the connection of a plastic pipe with DN 100 for
the inlet or DN 70 for ventilation can be carried out using
connection clamps or rubber hoses with hose clamps*. To
prevent the high tension forces leading to deformation at the
connecting piece, a suitable supporting ring* must be pus-
hed into the upper end of the connecting piece (see Fig. D).
Inlet connection
Tank-lifting station
Abb. C:
All manuals and user guides at all-guides.com
4. Installation and assembly
Saw off
connecting pieces
Transition
hose piece
Supporting ring
Abb. D:
the side (for inlet pipe or manual diaphragm pump) using
II. Connections attached to the pre-scored areas at
bore hole with saw cap*, fitting of a suitable greases seal*
and insertion of a suitable plastic pipe (see Fig. E)
Tank-lifting station
Abb. E
* KESSEL accessory part
54
Pipe connection
Hose
clamps
Saw off con-
necting pieces
Hose
clamp
Pipe duct seal
Pipe connection

Publicité